Add auto-report message
This commit is contained in:
parent
a0a4d0c2c1
commit
318eb18e50
1 changed files with 5 additions and 1 deletions
|
@ -131,7 +131,10 @@ The final wiring should look like this:
|
|||
Bus communication only makes use of basic CAN features. No higher-level
|
||||
protocols such as CiA, EtherCAN, VSCP or similar are required.
|
||||
|
||||
Normal 11-bit CAN adressing mode is used.
|
||||
Normal 11-bit CAN adressing mode is used. For messages that support RTR, any
|
||||
module can send a remote transmission request and the addressed module will
|
||||
respond with the described message. A module may also send the message
|
||||
without being probed.
|
||||
|
||||
This is the list of supported message IDs:
|
||||
|
||||
|
@ -140,3 +143,4 @@ This is the list of supported message IDs:
|
|||
| 0x10 | feedback | any | yes | 2 | 0b00000KJI 0bHGFEDCBA | Feedback module status report (A..E = end switch D..H, F..J = empty switch D..H, K = reset switch, 0 = off, 1 = on) |
|
||||
| 0x11 | poweriface | any | yes | 2 | 0bHHHHHHHH 0bLLLLLLLL | Power module status report (0xHHLL are the contents of the 16-bit shift register) |
|
||||
| 0x21 | controller | poweriface | no | 1 | 0b00000MMM | Start dispensing from slot M (1-5) or stop all dispensers (M = 0) |
|
||||
| 0x4f | any | any | no | 1 | 0b0000000E | Enable (E = 1) or disable (E = 0) automatic status updates on all modules |
|
||||
|
|
Loading…