feat: read and print responses from barcode scanner feat: udev rule docs: add more usage examples
3.3 KiB
Honeywell Barcode Reader Config Tool
What?
A Linux tool for configuring Honeywell barcode scanners via USB.
Why?
I had obtained a used Honeywell Hyperion 1300G scanner, however it was locked down and secured with a password, and the password was unknown.
There is a Windows-only configuration tool from Honeywell called "EZconfig" with which the barcode scanners can be configured via USB, even when locked down.
To not rely on a Windows VM for configuring the scanner, I sniffed the USB traffic using Wireshark and extracted the relevant messages, and wrapped them in this tool.
Usage
First of all, compile the program using make
. It depends only on libusb-1.0
.
The configuration strings need to be provided as command line arguments. You can provide multiple:
./honeywell-config <string1> [... <stringN>]
The commands sent to the scanner are prefixed with >
, the (tokenized) responses from the scanner with <
.
In general, please refer to your scanner's manual for configuration strings.
Here are some examples.
Factory Reset
$ ./honeywell-config DEFOVR. DEFALT.
> DEFOVR.
< DEFOVR.
> DEFALT.
< DEFALT.
Factory Reset - In one command
$ ./honeywell-config "DEFOVR;DEFALT."
> DEFOVR;DEFALT.
< DEFOVR.
< DEFALT.
Switch Operation Mode
USBHID:
$ ./honeywell-config PAP131.
> PAP131.
< PAP131.
Keyboard:
$ ./honeywell-config PAP124.
> PAP124.
< PAP124.
Add Prefix to Output
The following adds the string FCKAFD
(ASCII hex 46 43 4B 41 46 44 20
) in front of every scanned barcode:
$ ./honeywell-config PREBK246434B41464420.
> PREBK246434B41464420.
< PREBK246434B41464420.
Note how this behaves differently from if you were to configure the scanner in-band via scanning config barcodes. There you would scan a lot of individual codes from the manual:
PREBK2.
K4K.
K6K.
- ...
K2K.
K0K.
MNUSAV.
On the USB config interface, all of that goes into a single string instead.
Query Current Beeper Settings
$ ./honeywell-config 'BEP?.'
> BEP?.
< BEPFQ12550,FQ2100,RPT1,ERR1,BEP1,BIP0,LVL0,EXZ,GRX,EXE,DFT,LED1.
List all Settings and Their Possible Values
$ ./honeywell-config '*.'
> *.
< BEPFQ1100-5000.
< BEPFQ2100-5000.
...
< AXXMOD0|1|2|3|4|5|6|7|8|9|10.
USB Device Access
Please note that this tool normally needs to run as root. Alternatively, you can set up a udev rule to grant access to the USB device to non-root users.
An example for this can be found in the file 99-honeywell.rules
.
Put this file into /etc/udev/rules.d
, and run sudo udevadm control --reload
to load the new ruleset.
Once you replug the scanner, you should have access to it as a regular user.
Adapting for Other Scanners
The tool currently has hardcoded USB vendor/product IDs for a Honeywell Hyperion 1300G in Keyboard or USBHID modes.
If you have a different Honeywell scanner, and the tool doesn't find it, you can try making this tool work for it:
-
Obtain the USB vendor and product IDs for your scanner, e.g. through
lsusb
. -
Replace the VID/PID in the following line of code in
honeywell-config.c
:libusb_device_handle *devh = libusb_open_device_with_vid_pid(ctx, 0x0c2e, 0x0b07);
-
Recompile the tool with
make
License
MIT License